Manufacturers Radiation Oncology Medical Physics Diagnostic Imaging Radiation Safety

Discounted Nuclear Medicine Equipment


Used - Nucline SPIRIT DH-V:
  • Variable Angle Dual-Head Digital Gamma Camera System for SPECT, Whole Body and Planar Studies
  • Six month old system
  • Includes:
N-DHV-D Nucline SPIRIT DH-V basic configuration
C-DHV-LEHR Low Energy High Resolution Collimator Set (Pair) + cart
C-DHV-MEGP Medium Energy General Purpose Collimator Set (Pair) + cart
C-DHV-LEPH Low Energy Pinhole Collimator + cart
N-DHV-ABC Autobody Contour Set (quantity 2)
GE Workstation GE Xeleris Workstation
UPS Uninterrupted Power Supply
7100-3 AccuSync ECG Gate
NMC-45 Co57 Flood Source, rectangular, 10 mCi

Optional Accessories (available from factory)
 
C-DHV-LEGP Low Energy General Purpose Collimator (Pair) + cart
C-DHV-LEUHR Low Energy Ultra High Resolution Collimator (Pair) + cart
C-DHV-HEGP High Energy General Purpose Collimator (Pair) + cart
Terms:
  • System Delivery 10 days A.R.O.
  • Used system, original installation date February 2004. System carries a full 12 month warranty beginning at the time of installation at your facility
 

Nucline SPIRIT DH-V: Variable Angle Dual-Head Digital Gamma
Camera System for SPECT, Whole Body and Planar Studies
 
N-DHV-D
Detectors:
  • Two rectangular jumbo FOV, high stability detectors assembled with high optical and mechanical quality.
  • Nal(Tl) scintillation crystal 585 x 470 x 9.5 mm
  • Photomultipliers: 55 pcs of high quantum efficiency PMTs/detector characterized by improved energy resolution, long-term stability and magnetic shielding.
  • Lead shielding thickness: 12 - 32 mm
 
Detector Electronics:
  • A compact, highly integrated, one-board, easily serviceable construction without tuning potentiometers
  • Computer controlled PMT autotuning processor for fast PMT gain adjustment
  • Computer controlled ODC (Optical Distortion Correction) electronics
  • High precision summation electronics
  • 3x pile up recovery and resolution enhancing technology for high count rate
 
Gantry:
  • New design easy-to-install dual-detector gantry
  • 180 and 101 or 90 degree variable angle head positions with high precision with high precision positioning
  • Small footprint robust mechanical design with improved safety factor
  • Industry standard CAN connected automation computer
  • Pre-programmed robotic gantry motions
  • Full automation motion calibrations
  • Maintenance-free mechanical design
 
Imaging table:
  • Universal imaging table for SPECT and whole body examinations
  • Motorized vertical movements (250 mm)
  • Motorized whole body gantry motion
  • Low attenuation (<5%) 2.5 mm thin aluminum pallet
  • Max 400 lb patient weight
 
Nucline Digital Gamma Camera Electronics and Acquisition Console:
  • 4 independent energy channels
  • Multi-channel analyzer (resolution: 1024)
  • Persistence monitor function
  • Digital energy- , linearity, and uniformity correction by 48 bit digital signal processing
  • IBM compatible computer systems with a min. of: Intel Pentium III; 256 Mb RAM; 30 Gb hard disk drive; CD-ROM drive; 8 Mb video memory; Ethernet card (with UTP connector); keyboard; mouse; Acquisition console stand
  • 17" LCD monitor
 
NEMA Specifications:
  • Field of view: 530 x 390 mm
  • Energy range: 20-600 keV
  • Intrinsic energy resolution for Tc99: 9.9%
  • Uniformity:
    • differential CFOV: 1.9% integral CFOV: 2.4%
    • differential UFOV: 2.4% integral UFOV: 2.9%
  • Intrinsic spatial resolution: 3.6 mm (FWHM)
  • Intrinsic linearity:
    • differential CFOV: 0.18 mm integral CFOV: 0.38 mm
    • differential UFOV: 0.20 mm integral UFOV: 0.40 mm
  • Count rate with full correction: > 220,000 cps
 
Accessories:
  • Source holder for detector tuning
  • User manuals
 

Additional Accessories (Included)
 
 
Low Energy High Resolution Collimator Set (Pair) + cart
  • Designed for WB bone, bone spots, thyroid, general SPECT, lung, GI bleeding, hepatobiliary system
  • Can be used for cardiac SPECT
  • Hole Length (mm): 35
  • Hole Size (mm): 1.5
  • Septal Thickness (mm): 0.16
  • Nominal Energy (keV): 140
  • Septal Penetration at Nominal Energy: 1.0%
  • Geometric / System Resolution at 10 cm (FWHM mm): 6.5 / 7.4
  • Geometric / System Sensitivity +/- 7% (cpm/uCi): 180 / 150 *
          * Measured with 99mTc-in 20%-window
C-DHV-LEHR
Medium Energy General Purpose Collimator Set (Pair) + cart
  • Used for studies in the medium energy range such as In-111 and Ga-67. Also for low dose I-131 (<1 mCi).
  • Hole Length (mm): 35
  • Hole Size (mm): 2.5
  • Septal Thickness (mm): 1.2
  • Nominal Energy (keV): 300
  • Septal Penetration at Nominal Energy: 1.9%
  • Geometric / System Resolution at 10 cm (FWHM mm): 11.1 / 11.6
  • Geometric / System Sensitivity +/- 7% (cpm/uCi): 330 / 200 *
      * Measured with 67Ga-in 20%-window
C-DHV-MEGP
Low Energy Pinhole Collimator + cart
  • Hole Length (mm):   ~200
  • Hole Size (mm):   3 / 5 / 7
  • Nominal Energy (keV):   200
  • System Resolution at 10 cm (FWHM mm): 3.9 / 5.9 / 9.1
  • System Sensitivity +/- 7% (cpm/uCi): 160 / 550 / 850
C-DHV-LEPH
Removeable Autobody Contour Set
  • quantity 2 included in quotation (one for each head)
N-DHV-ABC
GE Xeleris Workstation
  • For Nuclear Medicine, PET, Hawkeye, and PET/CT Imaging
  • J3700JA Xeleris Desktop Workstation, includes 21" CRT monitor
  • See enclosed literature for a full description of system
GE Workstation
PowerRight Uninterrupted Power Supply
  • 12 hour operating time
UPS
AccuSync 71, 3 Lead ECG Gating System 7100-3
Co57 Flood Source, 16 x 24", 10 mCi
  • calibration date was six months ago
NMC-45

Optional Accessories (available from factory)
 
 
Low Energy General Purpose Collimator Set (Pair) + cart
  • Designed for WB bone, bone spots, thyroid, general SPECT, lung, GI bleeding, hepatobiliary system
  • Can be used for cardiac SPECT
  • Hole Length (mm): 35
  • Hole Size (mm): 1.9
  • Septal Thickness (mm): 0.20
  • Nominal Energy (keV): 140
  • Septal Penetration at Nominal Energy: 1.1%
  • Geometric / System Resolution at 10 cm (FWHM mm): 8.2 / 8.9
  • Geometric / System Sensitivity +/- 7% (cpm/uCi): 320 / 260 *
         * Measured with 99mTc-in 20%-window
C-DHV-LEGP
Low Energy Ultra High Resolution Collimator Set (Pair) + cart
  • Designed for superb resolution with poor sensitivity, can be used for excellent quality whole body and SPECT examinations
  • Hole Length (mm): 40
  • Hole Size (mm): 1.4
  • Septal Thickness (mm): 0.16
  • Nominal Energy (keV): 140
  • Septal Penetration at Nominal Energy: 0.4%
  • Geometric / System Resolution at 10 cm (FWHM mm): 5.4 / 6.5
  • Geometric / System Sensitivity +/- 7% (cpm/uCi): 133 / 100 *
        * Measured with 99mTc-in 20%-window
C-DHV-LEUHR
High Energy General Purpose Collimator Set (Pair) + cart
  • Used for whole body and spot imaging of I-131.
  • Hole Length (mm): 55
  • Hole Size (mm): 3.4
  • Septal Thickness (mm): 1.6
  • Nominal Energy (keV): 364
  • Septal Penetration at Nominal Energy: 5.9%
  • Geometric / System Resolution at 10 cm (FWHM mm): 11.6 / 12.2
  • Geometric / System Sensitivity +/- 7% (cpm/uCi): 340 / 75 *
         * Measured with 131I-in 20%-window
C-DHV-HEGP

Back to Used Products Page   |    PDF - Printable Page


Harpell Associates Inc.,
1272 Speers Road, Unit 2, Oakville, Ontario, Canada, L6L 2X4
Phone (905) 825-2588, Fax (905) 825-0234, Toll Free: 1-800-387-7168
Email:  Info@Harpell.ca